Catalogue


Mine fan with electric drive VME-6, VME-6/1

The VME-6, VME-6/1 local ventilation fans are intended for ventilation of blind workings in gaseous(methane)-and-dusty coal and ore mines at air density of up to 1.3 kg/m3 , temperature from 268 to 308 K, dust content of air of up to 50 mg/m3 , and relevant humidity of up to 95% (at 298 К).
Unitized equipment set provides two options of control (manual and automatic), unit operation in normal and reverse modes; partial adjustment of fan delivery due to the change of engine speed and turning the wheel blades of a distributor while running; automatic activation of a reserve fan in case of emergency outage of the running fan; automatic load transfer to a low voltage mode; automatic reclosure of fan drive when it shuts down during the short-term loss (to 9 s) or drastic mains voltage drop; air stream reverse without fan stoppage. In case of emergency the unit automatically shuts down. A controller is given light and sound signals. According to the safety requirements, the present mine workings ventilation unit consists of two fans: a running and a reserved one and a set of tools for air stream reversion and shift from running to reserved fan.

Advantages:

  • blades of the fan are made of non-inflammable material
  • if temperature exceeds the normal value, the fan can be shut down
  • economic
  • can be applied for small mine workings ventilation
  • fans’ design allows concatenating of two fans in order to rise pipeline pressure

Specifications:

Name
VME-6
VME-6/1
Nominal diameter, mm
630
630
Rated capacity, m3/s
7
7
Total rated pressure, Pa
2500
2500
Maximum overall efficiency
0.68
0.68
Electric drive power, kW
25
25
Rotation speed, rpm
3000
3000
Sound power level, dB
118
107
Set mass, kg
420
510
Dimensions, mm
 
 
Height
975
975
Width
750
750
Length
1050
1870

Trade mark

Sanitary and epidemiological certificate

 

License issued by Federal Office of Ecological, Technological and Atomic control

 


To close a window |