The pusher should not be applied in explosive environment and also in the environment containing caustic fumes and gases which destroy metals, sealing and rubber.
Upon request of a customer the plant can produce the tropicalized construction of electrohydraulic pushers (index T2) to be used in latitudes with tropical climate
Operation conditions:
Ambient temperature, K (°C) |
|
Y2 version (temperate climate) | 313 (40)-233 (-40) |
T2 version (tropical climate) |
318 (45)-263 (-10) |
Working liquid |
|
Transformation oil (max) |
258 (-15)
|
Oil AMG -10 |
288 (15)-233 (-40) |
Relevant air humidity, % |
|
Temperate climate |
|
at 293 K (20°C) |
80
|
at 298 K (25°C) (upper index) |
100
|
Tropical climate |
|
at 300 K (27°C) |
90
|
at 308 K (35°C) (upper index) |
100
|
Altitude, m, max |
1000
|
Specifications:
Name
|
TE-80M
|
Average lifting force, N |
1500
|
Developed lifting force, N |
1725
|
Rod stroke, mm |
65
|
Rod lift time, s, max |
1.5
|
Rod back stroke time, s, max |
0.45
|
Electric motor: |
|
rated power, kW
|
0.45
|
rated voltage, V
|
380
|
Power consumption, W |
400
|
Weight, kg |
35
|