The fans are allowed to be used as main ventilation fans. The fan is installed vertically with a permissible deviation of axle from horizontal by not more than 30 degrees. The fan is suitable for air pipes with diameter 1000-2000 mm.

Advantages:

Specifications:

 

Name
Value
Nominal diameter, mm
1000
Rated capacity, m3/s
23
Max. deviation, %
minus 10
Total rated pressure, Pa
6350
Max. deviation, %
minus 10
Maximum overall efficiency
0.86
Max. deviation
minus 0.03
Electric drive power, kW
160
Motor type
3VRM280M4 (2VRM280L4)
Voltage, V
380/660, 660/1140
Rotation speed, 1/min
1500
Motor explosion protection level
PB Exdl (PB 3B)
Motor protection level
IP54
Height, mm, max
1450
Width, mm, max
1200
Set mass, kg, max
1900
Mid life before the first overhaul, hours, minimum
10000

Notes:
  1. Parameters specified in the table are given for density 1.2 kg/m3.
  2. Max. deviation of the figures, stipulated in lines 2, 3, 4 of the table are not limited.
The product is certified in GOST R system.